thermotechnoogymd@gmail.com
+373 76 539 259
mun. Chisinau sat. Staucenu str. Bucovina 27
Thermotechnology
Steam condensate heaters
Heating panels
Thermostats and accessories
consumption 325 W/hour
ΠΚΗ-16
- Based on 16 aluminum sections
- Starting power: 1.6 kW (1-7.3 А)
- Power saving mode: 325 W/h
- Control: Built-in thermostatic unit
- Effective heating zone: 20 m²
- With ceiling height: 2,8 m
- Volum: 54 m³
- Dimensions (W/H/D): 570х1240х100 mm
- Weight: 22,1 kg (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 285 W/ora
ΠΚΗ-14
- Based on 14 aluminum sections
- Starting power: 1.4 kW (1-6.4 А)
- Power saving mode: 285 W/h
- Control: Built-in thermostatic unit
- Effective heating zone: 18 m²
- With ceiling height: 2,8 m
- Volum: 47 m³
- Dimensions (W/H/D): 570×1110×100 mm
- Weight: 18,6 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 200 W/ora
ΠΚΗ-12
- Based on 12 aluminum sections
- Starting power: 1.2 kW (1-5.5 А)
- Power saving mode: 200 W/h
- Control: Built-in thermostatic unit
- Effective heating zone: 16 m²
- With ceiling height: 2,8 m
- Volum: 40 m³
- Dimensions (W/H/D): 570×960×100 mm
- Weight: 16,5 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 170 W/ora
ΠΚΗ-10
- Based on 10 aluminum sections
- Starting power: 1 kW (1-4.5 А)
- Power saving mode: 170 W/h
- Control: Built-in thermostatic unit
- Effective heating zone: 14 m²
- With ceiling height: 2,8 m
- Volum: 35 m³
- Dimensions (W/H/D): 570×660×100 mm
- Weight: 13,4 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 150 W/ora
ΠΚΗ-8
- Based on 8 aluminum sections
- Starting power: 0.85 kW (1-3.9 А)
- Power saving mode: 150 W/h
- Control: Built-in thermostatic unit
- Effective heating zone: 12 m²
- With ceiling height: 2,8 m
- Volum: 30 m³
- Dimensions (W/H/D): 570×660×100 mm
- Weight: 11,2 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 100 W/ora
ΠΚΗ-6
- Based on 6 aluminum sections
- Starting power: 0.6 kW (1-2.7 А)
- Power saving mode: 100 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 8 m²
- With ceiling height: 2,8 m
- Volum: 20 m³
- Dimensions (W/H/D): 570х520х100 mm
- Weight: 7,7 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 85 W/ora
ΠΚΗ-4
- Based on 4 aluminum sections
- Starting power: 0.42 kW (1-1.9 А)
- Power saving mode: 85 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 6 m²
- With ceiling height: 2,8 m
- Volum: 15 m³
- Dimensions (W/H/D): 570х380х100 mm
- Weight: 5,7 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 3кW/ora
ΠΚΗ-6+Β
- Frame: Metal + blowing
- Starting power: 6 kW (1-27,3 А)
- Power saving mode: 3000 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 200 m²
- With ceiling height: 2,8 m
- Volum: 500 m³
- Dimensions (W/H/D): 1330×350×310 mm
- Weight: 43 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 85 W/ora
ΠΚΗ-0.5
- Frame: Metal case
- Starting power: 0.5 kW (1-2.2 А)
- Power saving mode: 85 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 7 m²
- With ceiling height: 2,8 m
- Volum: 17,5 m³
- Dimensions (W/H/D): 600×150×120 mm
- Weight: 10 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 85 W/ora
ΠΚΗ-0.5
- Frame: Metal case
- Starting power: 1 kW (1-4.5 А)
- Power saving mode: 170 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 14 m²
- With ceiling height: 2,8 m
- Volum: 35 m³
- Dimensions (W/H/D): 600×400×150 mm
- Weight: 20 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 170 W/ora
ΠΚΗ-1
- Frame: Metal case
- Starting power: 1 kW (1-4.5 А)
- Power saving mode: 170 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 14 m²
- With ceiling height: 2,8 m
- Volum: 35 m³
- Dimensions (W/H/D): 600×400×150 mm
- Weight: 20 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 335 W/ora
ΠΚΗ-2
- Frame: Metal case
- Starting power: 2 kW (1-9.1 А)
- Power saving mode: 335 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 27 m²
- With ceiling height: 2,8 m
- Volum: 67,5 m³
- Dimensions (W/H/D): 1200×400×150 mm
- Weight: 30 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Consum 535 W/ora
ΠΚΗ-3
- Frame: Metal case
- Starting power: 3 kW (1-13.6 А)
- Power saving mode: 535 W/h
- Control:Built-in touch for PCN
- Effective heating zone: 40 m²
- With ceiling height: 2,8 m
- Volum: 100 m³
- Dimensions (W/H/D): 1080×540×150 mm
- Weight: 43 кг (gross)
- Minimum voltage: 220 V
- Frequency: 50 Hz
- Type of current: Alternating, single-phase
Control unit
Programmable PRO
- 50 000 load cycles
- Temperature correction 0...+30С
- Built-in timer
- OTED mode
- LOGER consumption
Control unit
for PNK metal
- 50 000 load cycles
- Temperature correction 0...+30С